Structured cabling MDF room terminated and labeled by IronClad Integrated Systems
Home / Commercial / GC & Subcontracting
Division 27 & Division 28 Partner · North & Middle Georgia

One accountable low-voltage sub from rough-in to closeout.

General contractors, electrical contractors and construction managers partner with IronClad Integrated Systems to keep cabling, access control, cameras, security, fire alarm and gate automation coordinated on schedule across North & Middle Georgia.

Submit Plans for a Bid →View Capability Statement
Subcontracting Scopes

Clear division of scope — zero gray areas between trades

Low-voltage jobs stall when nobody owns the handoff between doors, power and data. We spell out exactly what we self-perform and what we coordinate with Div 08, Div 26 and civil trades before mobilization.

Div 27 · Communications

Structured Cabling & Rack Infrastructure

Self-Performed

  • Cat5e, Cat6 & Cat6A horizontal station cabling, J-hook pathways and bridal rings
  • MDF/IDF 2-post and wall-mount racks, patch panels, ladder rack and wire managers
  • Backbone fiber pulls, enclosures and demarc extensions where specified
  • Machine-printed port/faceplate labeling and pass/fail test records per contracted scope
Div 28 · Electronic Safety & Security

Access Control, Intrusion & IP Video

Self-Performed + Hardware Coordination

  • Card readers, keypads, door controllers, request-to-exit sensors and door contacts
  • Early coordination with Div 08 door hardware & Div 26 power/fire-alarm release relays
  • Commercial intrusion panels, motion/glass-break zones and cellular communicators
  • PoE IP surveillance cameras, NVR rack head-ends and field aiming schedules
Div 28 / Div 32 · Life Safety & Perimeter

Commercial Fire Alarm & Automated Gates

Scoped & Trade-Coordinated

  • Fire alarm rough-in, initiating/notification circuit pulls, device trim and upgrades within authorized scope
  • Coordination with Div 26 electrical, HVAC duct-detector relays, elevator recall and monitoring providers
  • Slide, swing and barrier gate operators, safety photo-eyes, vehicle loops and entry pedestals
  • Coordination with site/civil trades on concrete operator pads and underground sleeves
Project Fit & Delivery

Built for commercial construction schedules

We bid and deliver commercial projects across North & Middle Georgia where responsive communication, clean ceiling pathways and complete closeout packages matter.

  • New Construction & Ground-Up Shells: Conduit/pathway review, rough-in, MDF/IDF buildout & trim
  • Tenant Improvements (TI) & Build-Outs: Fast-turn office, medical, retail & warehouse fit-outs
  • Renovations, Cutovers & Retrofits: Phased cutovers in occupied facilities without disrupting tenants
  • Closeout Discipline: As-builts, device/port schedules, O&M packets and owner training per contracted scope
Print / Save Capability Statement →Vendor Onboarding: services@ironcladintegratedsystems.com

Marked As-Built Drawings

Updated cable paths, panel locations, camera IDs and zone numbers.

Test & Labeling Schedules

Port maps, reader/door schedules and device test logs when in contracted scope.

O&M Manuals & Cut Sheets

Organized product data sheets, warranty terms and maintenance guidance.

Owner Handover & Training

Clean admin credential transfer and walkthrough with facility staff.

Standards the work followsNFPA 72Fire alarm and signalingNFPA 70National Electrical CodeUL 325Automated gate operators & safetyUL 294Access control equipmentUL 681Intrusion alarm installationTIA-568Structured cablingTIA-606Labeling and administrationTIA-607Bonding and groundingNEC Art. 760Fire alarm circuitsNEC Art. 725Class 2 & Class 3 low-voltage
Estimating & Bid Desk

Submit Plans & Specifications for a Bid

Upload drawings, Div 27 / Div 28 spec sections, scope sheets or addenda (or include a BuildingConnected / Procore / plan-room link). You will receive an immediate email confirmation.

Low-Voltage Scopes Included in Bid
Note relevant spec sections (Div 27 / Div 28), door/drop counts if known, or paste a BuildingConnected / Procore / Dropbox link for large plan sets.
Accepted: PDF, JPG, PNG, WEBP, DWG, DOC/DOCX, XLSX, CSV, ZIP. Never upload files containing active passwords or alarm codes.
Direct response within 1 business day · Recorded directly into our CRM queue.
Request ServiceRequest a Quote